Forum Replies Created
-
AuthorPosts
-
Got the 590 primer from our local wyse sales guy and it works fine….
be interesting to know if anyone else has issues with the wyse.com padded image like i did
thanks
FOUND IT.. well kind of
its the 590 padded image thats the problem, i went back to the 581 padded image and have no issue at all
Hi ConfGen
Thanks for reviewing my post, yes basically the S30 states its 590.01.01, correctly WDM database records it as 590.01.01, its set to CEN, but no matter what i do it keeps imaging every checkin.
its a good thing im bald or i would pull my hair out, im at the point now where i may build another WDM and try the image, i dont really want to reload it due to all the work i put into its setup, groups etc.
iv used unpadded, padded, custom images, every build number going,
our S10’s are working fine with DDC,
do you know of anywhere i can check this reporting in process, look at what the s30 is giving wdm when it checks in or something like that, i have raised a wyse support incident but last time i did that the guy told me its not possible to change a build number….. so my confidence is low
thank
s05195
ps your a ledgend for all ur community help 😀 we appreciate you
THANKS !!! what can i say you are again the best, wish Wyse helped this much.. 😆
thanks works now
Hi,
Sorry i have been away, Ok go into account management and set the ISUR account password to something you want, then go to IIS manager, default website (Rapport one)and untick allow IIS to conterold password, type in the new password you set for the ISUR account, then go to default website do the same, restart and try see if its works.
Thanks alot this works great…
oh now i look very stupid !, yes you did say go to the end and add the lines,,,, I got a bit carried away and being clever i didnt read it properly and simply went to the instructions.
Thanks once again.. sorry that will teach me to get carried away. 😮
Got slighty excited then, Ok I pulled the device config and went into the folder interpub/rapport/s30cfg <– what i called the config
Edit the Settings.reg file but it does not have MinorBuild feilds for me to change any idea’s
I’m working on a Wyse S30 CE.net
Thank you loads, I tried explaing this to Wyse support and they were like Toadstools !!! they kept trying to send me version 579.1 from my explanation….
😛
try these and let me know i had this problem and found it to be the anonymous account password being out of sync on IIS- if u want more on that e-mail me and ill guide you through setting it..
1. Verify the inetpubwwwroothserver.dll has anonymous access enabled.
2. Try resetting the IUSR account password in both Computer Manager and the IIS Web properties
3. Increase the permissions of the IUSR account to avoid potential account restrictions.
4. Applications that use IIS must not be running on the WDM box. For instance, Dameware.
5. HP/Compaq management agents can use port 80 which will conflict with Hserver. Remove them.
6. Test this link for a response: http://localhost/hserver.dll?&V99
Also try replacing localhost with the HServer IP.
Try prompting the user account specified for anonymous access to local admin temporarily and repeat above.
You should get something like the following
2007|9|3|11|47|24|
YEAR | MONTH | DAY | HOUR | MINUTE | SECONDThis value will continue to update with each F5 (refresh)
If it’s getting a value back then HServer is running. If prompted for logon then it’s a permissions issue.7. Tick/untick the allow anonymous connections box under IIS to the default website and reboot the server.
-
AuthorPosts