Pstem

Forum Replies Created

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • in reply to: Disconnecting USB devices #24425
    Pstem
    Member
    • Total Post: 3
    • Newbie

    Sorry, not sure I understand- I’m using the xen.ini straight from the confgen and that is working fine. The user signs in through the wyse login and that authenticates against AD and signs them into their WIN7 desktop.

    in reply to: Disconnecting USB devices #24422
    Pstem
    Member
    • Total Post: 3
    • Newbie

    Sure, here it is:

    ;*************************************************************
    ;* *
    ;* This xen.ini file was generated with the *
    ;* Configuration File Generator 6.4.08 *
    ;* Copyright by Thomas Moellerbernd *
    ;* *
    ;* https://technicalhelp.de *
    ;* *
    ;*************************************************************

    ;*************************************************************
    ;* General 1 *
    ;*************************************************************

    autoload=0
    AdminMode=yes Username=********* Password=**********
    Privilege=Low Lockdown=yes EnableNetworkTest=yes ShowDisplaySettings=Yes
    EnableGKey=yes

    ;*************************************************************
    ;* General 2 *
    ;*************************************************************

    Locale=English

    Device=vusb ForceRedirect=0x07b4,0x0228,0x03,0x01,0x01

    ;*************************************************************
    ;* General 3 *
    ;*************************************************************

    ShutDown=turnoff

    ;*************************************************************
    ;* Peripherals *
    ;*************************************************************

    Language=Uk

    ;*************************************************************
    ;* Display *
    ;*************************************************************

    Screensaver=60
    Dualhead=no MonitorAutoDetect=yes

    ;*************************************************************
    ;* Time *
    ;*************************************************************

    Timeserver=0.uk.pool.ntp.org Timeformat=”24-hour format” Dateformat=dd/mm/yyyy
    ; If you are using an older version of WTOS code please use:
    ; TimeZone= ‘GMT’ ManualOverride=yes Daylight=yes Start=030507 End=100507 TimeZoneName=GMT DayLightName=GMT

    TimeZone=’Greenwich Mean Time’ ManualOverride=yes Daylight=yes Start=030507 End=100407 TimeZoneName=”GMT Standard Time” DayLightName=”GMT Daylight Time”

    ;*************************************************************
    ;* Network *
    ;*************************************************************

    BootpDisable=yes
    DNSIPVersion=ipv4
    SignOn=No
    DisableDomain=yes
    DomainList=”*******”
    MaxVNCD=1
    VncPassword=”**********”
    VncPrompt=No Accept=5

    ;*************************************************************
    ;* ICA *
    ;*************************************************************

    SessionConfig=ICA SessionReliability=yes AudioQuality=High

Viewing 2 posts - 1 through 2 (of 2 total)