  • in reply to: Wyse 9450XE RDP 7 or Windows Embedded Standard 2009 #20667
    philb
    Member
    • Total Post: 3
    • Newbie

    The answer given is correct, but having purchased after market Flash upgrades I have plenty of room, so how would you get a new image to fit?

    Lets say hypothetically you purchase 2 or 4GB flash module for this legacy hardware. How do you fit image on it? Obviously Wyse would frown on such things, but if they want to keep customers they have to realise these are hard times and some of us have to make do and mend until the economic landscape makes it feasible for us to buy newer models. Time they looked at there customer base and helped

    in reply to: Changing Imageable setting in WDM #13191
    philb
    Member
    • Total Post: 3
    • Newbie

    Hi There are two methods I can think of.

    One. Delete the automatic detected version and manually enter the details ensuring at the end you check the imageable box.

    Two. Coming up as “imageable” “No” usually means it won’t actually work. There are several issues
    a, are you on same subnet as WDM/Rapport?
    b. seperate subnet
    c. WAN

    If a. above
    Usually if on same subnet make sure you are not using WDM as DHCP as well. WDM should be fixed IP. Disable DHCP in services on WDM. Delete workstation you want to image. Rediscover is it imageable?

    if b. or c. above it will be problems with helpers and or switches I have all Cisco (Core layer 3) put IP helpers on routers and check switch for fastport.

    Best suggestions I have at this time, somebody else may have more