Cannot get past TS Gateway

Tagged: , , ,

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #50437
    jharrison
    Participant
    • Total Post: 23
    • Regular Joe
    • ★★

    Please see configuration file below. I am using a Wyse 3010 trying to connect to a Windows terminal server with a gateway. Each time I try to log in, I get looped back to the log in page and the System Information shows an error: “RDP: Connection failure: TS Gateway credentials or Domain invalid(-2)” I have this same config file loaded onto another wyse within the Agency and it is able to access the terminal server just fine, but for some reason the one I am working with will not. The account I am using to log in has full admin rights and is still not working. Please let me know if there is any other information that I need to include. Thank you.

    ;*************************************************************
    ;* *
    ;* This wnos.ini file was generated with the *
    ;* Configuration Generator 8.2.01 *
    ;* Copyright by Thomas Moellerbernd *
    ;* *
    ;* https://technicalhelp.de *
    ;* *
    ;*************************************************************

    ;*************************************************************
    ;* General 1 *
    ;*************************************************************

    autoload=2
    AdminMode=yes Username=user Password=pass

    ;*************************************************************
    ;* General 2 *
    ;*************************************************************

    FactoryDefault=yes
    EnableCacheIni=yes
    PrinterMap=printer.txt

    ;*************************************************************
    ;* General 3 *
    ;*************************************************************

    AutoSignoff=yes Shutdown=yes
    Shutdowncounter=0 Unit=second
    ShutDown=turnoff

    ;*************************************************************
    ;* Privilege *
    ;*************************************************************

    Privilege=None HideSysInfo=yes SuppressTaskbar=yes

    ;*************************************************************
    ;* Peripherals *
    ;*************************************************************

    Language=Us ManualOverride=yes

    ;*************************************************************
    ;* Time *
    ;*************************************************************

    Timeserver=time.nist.gov Timeformat=”12-hour format” Dateformet=dd/mm/yyyy
    TimeZone=’GMT – 08:00′ ManualOverride=yes Daylight=yes Start=030207 End=110107 TimeZoneName=”Pacific” DayLightName=”Pacific”

    ;*************************************************************
    ;* Network *
    ;*************************************************************

    SignOn=No

    ;*************************************************************
    ;* Printing *
    ;*************************************************************

    Printer=LPD1 LocalName=”HP LaserJet Printer” Host=192.168.1.25 PrinterID=”HP-LaserJet” Class=PCL6 Enabled=yes

    ;*************************************************************
    ;* General Session *
    ;*************************************************************

    SessionConfig=ALL DisableSound=Yes

    ;*************************************************************
    ;* RDP *
    ;*************************************************************

    ;————————————————————-
    ;- RDP Session 1 –
    ;- Each line but the last must end with a ‘\’ –
    ;————————————————————-

    CONNECT=RDP \
    Host=host \
    Description=”Remote Connection” \
    AutoConnect=yes \
    Fullscreen=yes \
    Rdp_No_Wallpaper=yes \
    Rdp_No_Dragging=yes \
    UniSession=yes \
    Domainname=domain \
    Disablesound=Yes \
    TSGWEnable=yes \
    TSGWUseSameInfo=yes \
    TSGWServer=server \
    TSGWDomainName=domain \
    LocalCopy=no

     

    #50438
    ConfGen
    Keymaster
    • Total Post: 10696
    • Jedi Master
    • ★★★★★★★

    Are both units the same?
    Same firmware version?

    CG

    #50440
    jharrison
    Participant
    • Total Post: 23
    • Regular Joe
    • ★★

    Yes, both units are the same and have the same firmware.

    #50460
    jharrison
    Participant
    • Total Post: 23
    • Regular Joe
    • ★★

    Is there a setting to allow updating the ini file from the Global INI tab under System Tools itself so I don’t have to load it each time I make a change?

    #50461
    ConfGen
    Keymaster
    • Total Post: 10696
    • Jedi Master
    • ★★★★★★★

    No

    CG

    #50463
    jharrison
    Participant
    • Total Post: 23
    • Regular Joe
    • ★★

    ConfGen,

    Thank you for your help. The issue was with the firmware. I was comparing it to another device that I had in my office, but the one at the other site is an older firmware version. Once I downgraded the firmware, I was able to log in without looping. If there is a way to mark this thread as solved, please let me know and I will take care of it.

Viewing 6 posts - 1 through 6 (of 6 total)
  • You must be logged in to reply to this topic.