C90LE display problem while running banking software.

  • This topic is empty.
Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #5385
    raheel_i
    Participant
    • Total Post: 73
    • Back Stage Pass
    • ★★★★

    Hi,

    I have experienced a display problem on C90LE (graphic= S3 Chrome9 HCM IGP INTEGRATED GRAPHIC CARD) while running the banking software on it .The software initializes but eventually it endup leaving the thinclient hanged up with blank display screen. any suggestions???

    THANKS.

    #16732
    raheel_i
    Participant
    • Total Post: 73
    • Back Stage Pass
    • ★★★★

    I finally found the solution for C90LE display , by lowering the “FRAME BUFFER SIZE ” of video memory from bios TO 64 OR 128 MB . Its working fine .

    #16736
    ConfGen
    Keymaster
    • Total Post: 10696
    • Jedi Master
    • ★★★★★★★

    Great, thanks for letting us know.

    CG

Viewing 3 posts - 1 through 3 (of 3 total)