Logon Has Timed out, Please Logon Again

Tagged: 

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #51218
    Citrixwms
    Participant
    • Total Post: 11
    • Regular Joe
    • ★★

    Hello,
    we are trying to use this Wyse 3040 with 8.6_027 as kiosk machines(Passing both user name and password from Mac file). .

    we are presenting user with 2 published application, when user click an application to launch after few minutes machines are getting Enter Credential prompt(Logon has timed out, please login again).

    Tried ScreenSaver=0 LockTerminal=0 but its still getting locked.

    Any ideas?

    #51221
    brian1020
    Participant
    • Total Post: 259
    • Jacked into The Matrix
    • ★★★★★★

    I see two sections in my WMS.ini that may address what you’re looking for: possibly the ExpireTime parameter in the first section and as you already stated you have lock terminal set to 0

    SignOn=Yes ExpireTime=0 RequireSmartCard=No SCRemovalBehavior=0 IconGroupStyle=Default DisableGuest=No

    ScreenSaver=20 LockTerminal=0 Type=2 Image=”” PictureTimer=6 PictureOrder=Default PictureCheck=Default PictureLayout=center Sleep=60 Unit=No

    #51227
    Citrixwms
    Participant
    • Total Post: 11
    • Regular Joe
    • ★★

    i have tried this settings but its still getting locked out.

    #51263
    ConfGen
    Keymaster
    • Total Post: 10696
    • Jedi Master
    • ★★★★★★★

    Add
    SessionConfig=ICA Timeout=no
    to the WMS Advanced section.

    CG

    #51286
    Citrixwms
    Participant
    • Total Post: 11
    • Regular Joe
    • ★★

    This Solved the issue for me,Thank you.

Viewing 5 posts - 1 through 5 (of 5 total)