Forum Replies Created
Viewing 7 posts - 1 through 7 (of 7 total)
-
AuthorPosts
-
July 30, 2021 at 9:33 am in reply to: Downgrade 9.1 to 8.6 – 8.6 settings not avalable in Wyse Management Suite #105876February 15, 2021 at 10:48 am in reply to: Downgrade 9.1 to 8.6 – 8.6 settings not avalable in Wyse Management Suite #76138
Yes, Fisrt i downgraded the 3040 via USB imaging.
After i re-registred it to WMS. I can’t see the 8.6 settings, only show the 9.1 settings.
Regards.
February 15, 2021 at 10:27 am in reply to: Downgrade 9.1 to 8.6 – 8.6 settings not avalable in Wyse Management Suite #76113No this is the problem, when i delete the device, and re-register it, i can’t access to the 8.6 settings. only the 9.1 settings.
February 15, 2021 at 10:09 am in reply to: Thinos 9.1 Windows RDP – Print Screen key not working #76112Not yet
You have to disble the secure boot in the Bios.
For me the VNC problem is present when i updated thin os 8.6 to 9.1 directly.
After update 8.6 to 9.0 and 9.0 to 9.1 and put the WMS (3.1) IP to “Serveur VNCD” on the Service VNC settings .
It’s ok.
Wyse 3040 and ThinOS 9.1.1131 and WMS 3.1 559
Regards
Hello Peter,
I’ve got the same problem when i tried to upgrade directly 8.6 to 9.1.
So I update 8.6 to 9.0 and after 9.0 to 9.1 and it’s ok now.
regards.
-
AuthorPosts