It is simple really. My 3040 is registered into my WMS, which should allow the thin to connect to my view server. Everything was working up to there. It’s when the thin tries to connect to the vm that it stopped working.
That being said, I managed to solve my problem by looking into the PCoIP Secure Gateway option in Horizon. By reading some stuff about it, I found out that an IP address should be in there instead of an URL, like I had.
I really thought the problem was within the thin client, but it seems like it was in Horizon!
Thanks for your help!
I just tried with blast and it works well. I really would rather use PCoIP, though.
I dont really understand why blast would work and not PCoIP
I am publishing it with PCoIP only, and I have a 3040 running with PCoIP.
I haven’t tried Blast. Should I? Why?
Thanks for your help
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |