Configuração wyse s10 com server 2012

Good afternoon, I received a request that is beyond my knowledge, I had never configured a client, I have 5 Thin client Wyse s10 I need to configure with a…

Reply To: How to best migrate Terminals with separate mac.ini filer to WMS

…a version of WTOS code < 7.0.1_13 please use: ; Resolution=DDC Refresh= Screen=1 Resolution=DDC ;Screen=1 Resolution=1280×1024 Desktop=logo.jpg Screensaver=”10″ LockTerminal=no Type=2 Image=logo.jpg ;************************************************************* ;* Time * ;************************************************************* Timeserver=ntp.company.com Timeformat=”24-hour format” Dateformat=dd/mm/yyyy…

Redirected COM port takes 5 minutes to send data

Windows Server 2012 R2 RDS session collection using full desktop. Scale connected to 5010 by USB to serial adapter. Latest 5010 firmware installed. Data appears within seconds using Putty –…

Reply To: “virtual” com-port

Basically the port maps through in the ICA session so you would have to connect the unit and pass the command from within the session. I would go with a…

WNOS.ini assistance

…and connects without issue: CONNECT=RDP BrowserIP=ctp.techpro.com Host=ctp.techpro.com Description=”TechPro-TEST-CTP” Icon=icon1.ico Colors=high Fullscreen=yes Resolution=default LocalCopy=no However, the ICA connection to the Citrix Published Desktop will not work unless I declare a PNLiteServer…

T50 power icon missing from taskbar

…AuthType=OpenSystem ;************************************************************* ;* Chromium * ;************************************************************* Browser.Homepage=intranet.mycompanybenelux.com DefaultBrowser=no CONNECT=RDP Description=”RDP – AX …” Colors=16m Host=”IB-RDS” Fullscreen=yes Domainname=mycompanybenelux.com Ping=yes LocalCopy=no CONNECT=RDP Description=”Free – No full screen” Colors=16m Fullscreen=No Resolution=1280×1024 Domainname=mycompanybenelux.com Resolution=default…

T10 Dual USB serial converter

…1 become COM 2 and vice versa. How Wyse assign COM ports ? How to know the correspondence between USB and COM ? Can we set this correspondance ? Thanks…

Thin client won’t connect to Citrix after new switches

…[9622]PASS -guest@wyse.com 230 07:02:32 10.149.220.61 [9622]sent /Winterm/wnos/C10_bios.bin 550 2 ftp server log thin client connected to old switch: 07:23:25 10.149.220.61 [9632]USER anonymous 331 07:23:25 10.149.220.61 [9632]PASS -guest@wyse.com 230 07:23:25 10.149.220.61…

Cant make WTOS stop autologging into VDI

…Rootpath=pub/wyse Rapportserver=wdm.requestfoods.com AdminMode=yes Admin-Username=***** Admin-Password=***** Privilege=None HideSysInfo=yes HidePPP=yes HidePN=yes HideConnectionManager=yes ;************************************************************* ;* General 2 * ;************************************************************* DisableButton=yes Inactive=0 Serial=COM1 Baud=19200 Parity=None Stop=1 Size=8 Flow=None Device=audio Volume=12 ;************************************************************* ;* General 3…

SAN/UCC certificate for RDP connections

…‘rdp1.corp.mydomain.com’ … ‘rdp4.corp.mydomain.com’). Is there anything I should consider? Will it work? Will I have some troubles that way? Maybe I should change the 2nd level wildcard to 1st level…